Pipeline System Administration
Performing system administration operations
8-16 Preliminary January 30, 1998 Pipeline User’s Guide
To reset the unit:
1
Open the Sys Diag menu.
2
Select Sys Reset and press Enter.
The Pipeline asks you to verify that you want to reset.
0=ESC
1=Reset
3
To confirm, type 1.
During a reset, the Pipeline clears active connections and runs its Power-On Self
Test (POST), just as it would if the unit were power-cycled. If you do not see the
POST display, press Ctrl-L.
While the yellow FAULT LED on the front panel is ON, the Pipeline checks its
memory, configuration, installed modules, and lines. If any of the tests fail, the
FAULT LED remains on or blinking.
The alarm relay remains closed while the POST is running and opens when the
POST completes successfully. When you see this message:
Power-On Self Test PASSED
Press any key...
Press any key to display the Main Edit Menu.