Configuring IPX Routing
Configuring IPX routing connections
Pipeline User’s Guide Preliminary January 30, 1998 4-31
To configure the site B Ascend unit:
1
Assign the Ascend unit a name if it does not already have one.
To assign the Pipeline a name, open the System profile and specify the name
in the Name parameter. For example:
Name=SITEBGW
2
Open the Connection profile for site A.
Set up the Connection profile like this:
Station=SITEAGW
Active=Yes
Encaps=MPP
Dial #=555-1213
Route IP=No
Route IPX=Yes
Bridge=No
Dial brdcast=N/A
Encaps options...
Send Auth=CHAP
Recv PW=*SECURE*
Send PW=*SECURE*
IPX options...
IPX RIP=Both
IPX SAP=Both
NetWare t/o=30
3
Close and save the profile.